DA14531
A line in April
The submitterzhang_lei75 points A replyProblem: figure 1 is a schematic diagram of the circuit board, we do we use the J - link connects p2, want to use Dialog SmartBond Flash Programmer 1.0.4. The codeless_531_datapump bin download to Flash U11 (model: AT25DF011 - SSHN - B).
Download process: in the official website to download the SDK codeless, version is: DA145xx_CODELESS_6. 380.12.6, in DA145xx_CODELESS_6. Find the codeless_531_datapump 380.12.6. Bin file, the codeless_531_datapump. Bin file in FlashProgrammer directory, open the Dialog SmartBond Flash Programmer 1.0.4, click on the "Browse" button, select codeless_531_datapump. The path to the location of the bin file, select the JTAG number "1", then click on the "Erase" button, a "Failed you SPI ports and pins", but then appeared "Successfully downloaded firware file to the board".
As is shown in figure 2.
Attachment | The Size |
---|---|
The principle diagram of the circuit | 19.12 KB |
Results after download via FlashProgrammer. Bin file | 60.73 KB |
A line in April
Hi Zhang lei,
Thank you for your questions.
Can try to useSmartsnippet ToolboxTo burn.At the same time can also check the wiring.
If there is a standard development board, you can use the big board on the JTAG mouth to burn.
Best regards,