Programming DA14580 using SUOTA

4 posts / 0 new
Last post
ashutosh.baheti
Offline
Last seen:5 years 8 months ago
加入:2015-05-05 22:43
Programming DA14580 using SUOTA

Hi,

I want to use the SUOTA feature of the DA14580 to program the device for the first time. I want to do this to reduce footprint and remove dependency from external programmers.
Can this be done in industrial level with many devices and can it be done to program the OTP?

If so are there some certain setting that need to be done?

Keywords:
Device:
JE_Dialog
Offline
Last seen:7 hours 27 min ago
工作人员
加入:2013-12-05 14:02
Hi Ashutosh, its not

Hi Ashutosh, its not practical to do that (in fact, not possible). SUOTA is a profile and itself has to be progammed first into a device before it can grab anything over the air. There are also other parameters like XTAL trimming that need to be done in production test environment.

At industrial level : if you are looking to put through volume, we have a solution for that also : a 16:1 parallel tester with full automation. Please look under the reference design and production test platforms for details. We have customers using this already in volume production. BR JE_Dialog

PiMios
Offline
Last seen:2 months 5 days ago
加入:2016-01-28 00:18
Hi BR, can you please provide

Hi BR, can you please provide more details on to where to find the documentation related to mass programming of SUOTA binary files? We are using the DA14680 chip with the Production Line Tool. We have been pointed to the CLI programmer, but we do not have a clear way to identify multiple DUTs or programming SUOTA over UART which is what the PLT uses.

Thank you,
Nick

JK_Dialog
Offline
Last seen:2 weeks 1 day ago
工作人员
加入:2016-08-22 23:07
Issue handled vial mail.

Issue handled vial mail. Used the Smart Snippets Studio script to identify the command process in cli_programmer for write_qspi_suota().