Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
4 posts / 0 new
Last post
epoulsen
Offline
Last seen:1 month 1 week ago
Joined:2020-08-28 12:19
32KHz vs internal 10KHz clk

Hi

For the low power mode in the 14585 chip ther is two options using an external 32 KHz or use the internal generated 10 KHz. In our design the 14585 run in BUCK mode and use Lithium coin cells as supply.

So in this setup do I gain anything with adding a 32KHz crystal instead of using the internal generated 10KHz?

Br Erik

Device:
PM_Dialog
Offline
Last seen:1 day 16 hours ago
Staff
Joined:2018-02-08 11:03
Hi epoulsen,

Hi epoulsen,

32 KHz晶体外部或内部RCX can be used a Low Power Clock (LPC).

In case of the external XTAL, please see section 5.3 from theAN-B-054: DA14585/586 Application Hardware Design Guidelinesto find the specification.

Regarding the SW, the LPC can be configured from CFG_LP_CLK macro in da1458x_config_advanced.h file.

Thanks, PM_Dialog

epoulsen
Offline
Last seen:1 month 1 week ago
Joined:2020-08-28 12:19

thanks but what is the benefit to use the external 32 KHz in this mode if there is any?

Br Erik

PM_Dialog
Offline
Last seen:1 day 16 hours ago
Staff
Joined:2018-02-08 11:03
Hi epoulsen,

Hi epoulsen,

The external crystal oscillator is more stable. According to the datasheet the accuracy of the RCX is +- 500 ppm and the accuracy of an XTAL is +- 250 ppm. Since you are using the DA14585 you can use the RCX.

Thanks, PM_Dialog