Dear Dialog Experts,
what is the difference between the provided firmware images? I was unable to find an answer to this question in UM-140. This document just mentiones them without any explanation. Is the only difference in the set of AT-command supported?
- CodeLess for DA14531 datapump (codeless_531_datapump.hex)
- CodeLess for DA14531 standalone (codeless_531_standalone.hex)
- CodeLess for DA14531 standalone SET TWO (codeless_531_standalone_set_two.hex)
Keywords:
Device:
Hi Sergei Bezroukov,
The codeless_531_datapump.hex is used to demonstrate the Binary mode functionality – please take a look here:
http://lpccs-docs.dialog-semiconductor.com/UM-140-DA145x-CodeLess/binarymode.html
The deference between codeless_531_standalone.hex and codeless_531_standalone_set_two.hex is the supported AT commands. Please see Table 8 :
http://lpccs-docs.dialog-semiconductor.com/UM-140-DA145x-CodeLess/atcommands.html#supported-at-commands-for-da14585-586-da14531-standalone-and-da14531-datapump
DA14531 datapump : supported AT commands for codeless_531_datapump.hex
DA14531 standalone (SET-ONE) : supported AT commands for codeless_531_standalone.hex
在comman DA14531独立(设置两个):支持ds for codeless_531_standalone_set_two.hex
Thanks, PM_Dialog