width pulse in counter

⚠️
Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
9 posts / 0 new
Last post
danmalper1
Offline
Last seen:6 months 2 weeks ago
加入:2020-01-03 19:13
width pulse in counter

Dear

I am using the SLG46620 device and the CNT components as counters, I would like to know if the width of the geerated set can be changed or is it by default.

Attached image.
Another question regarding this would be if it is possible to generate a pulse half the width of the one provided as an attachment in image 2.

Thank you

Regards

Attachment:
Device:
Device Number:
SLG46620
olehs
Offline
Last seen:2 months 2 weeks ago
Staff
加入:2018-02-07 11:40
Hi danmalper1,

Hi danmalper1,

Thanks for your question,

1. The Counters' pulse width is equal 1 period of CNT's clock. The width can be changed by changing the clock frequency. Clock can also be chosen as output from the other counter. Could you explain me want you want to do or provide the timming diagram and I will help you with the design.

2. Could you send me the design file with your project, because I don't understand the issue

Best regards,

Oleh Sapiha

danmalper1
Offline
Last seen:6 months 2 weeks ago
加入:2020-01-03 19:13
Dear Oleh Sapiha

Dear Oleh Sapiha

Thank you for reply. I send you the design and attach my question.

Regards

Daniel

Attachment:
olehs
Offline
Last seen:2 months 2 weeks ago
Staff
加入:2018-02-07 11:40
danmalper1,

danmalper1,

A quick checking of my understanding: the signal of various duty cycle is applied to input PIN (let's say PIN4). The other input PIN (let's say PIN5) is a selector. Depending on selector (PIN5) we need to divide by 2 the duty cycle or multiply it by 2 and apply it to the output. Am I correct?

If yes, then I have just created the design, I hope it help you to start

Please let me know if my understanding is correct

Best regards,

Oleh Sapiha

olehs
Offline
Last seen:2 months 2 weeks ago
Staff
加入:2018-02-07 11:40
Daniel,

Daniel,

I have updated my previous comment, please take a look

Have a nice day!

danmalper1
Offline
Last seen:6 months 2 weeks ago
加入:2020-01-03 19:13
你好Oleh pokalchuk Sapiha

你好Oleh pokalchuk Sapiha

It is a perfect configuration, but if I want to use in the same chip, it is not possible using CNT2/DLY2, because it is being use conect to ADC.

I am trying use with another CNT, but I am not getting the same result, as those have not UP and Keep connections. Do you know if it is possible using another CNT or other configuration?

再次非常感谢你

Regards

Daniel

olehs
Offline
Last seen:2 months 2 weeks ago
Staff
加入:2018-02-07 11:40
Daniel,

Daniel,

I believe, it is impossible to create this functionality without CNT(FSM) block, since you need to store the data(clock) which corresponds to the input pulse width. So the only way to do it is to use CNT(FSM).

By the way, SLG46620 has two CNT(FSM) block, so you can use another one (CNT4 instead of CNT2). CNT4 is 8bit counter and it can also work with ADC

Please let me know if you have any further question about the design or GreenPAK itself

Best regards,

Oleh Sapiha

danmalper1
Offline
Last seen:6 months 2 weeks ago
加入:2020-01-03 19:13
你好Oleh pokalchuk Sapiha

你好Oleh pokalchuk Sapiha

I have a question about the possibility of modify the model in greenpack and the need to use dff.

Attached below

Thank you

regards

daniel

Attachment:
olehs
Offline
Last seen:2 months 2 weeks ago
Staff
加入:2018-02-07 11:40
Dear Daniel,

Dear Daniel,

This DFF is used in another mode, when we need to produce a half of input pulse width, when SEL is equal 0. You are right that we don't need this DFF as well as 3-L0 (MUX) and 2-LUT2, when we need only to double the duty cycle. But they are necessary components for dividing the duty cycle

Best regards,

Oleh Sapiha