Load Sharing on LDOs, DA9063

⚠️
Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
2 posts / 0 new
Last post
JT20
Offline
Last seen:1 year 2 weeks ago
Joined:2020-04-23 13:42
Load Sharing on LDOs, DA9063

Hello,

I was wondering if the DA9063 LDOs can load share at common voltages. Particularily LDO1 and LDO 2.

Best - JT20

Device:
ED_Dialog
Offline
Last seen:1 month 3 weeks ago
Staff
Joined:2017-09-18 11:54
Hello JT20,

Hello JT20,

Yes, the LDOs can be used in parallel.

They need to have the same voltages and sequencer slots. You will also have to take into account thermal aspects.