Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
13 posts / 0 new
Last post
yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
For peripheral, how to filter/only accept certain device connection request?

Hi,

Our device is DA14682. I want the peripheral device only to accept our own central devices' connection request, but reject other devices. It seems the peripheral cannot read the central device name, is that true? And from this thread:https://support.dialog-semiconductor.com/forums/post/dialog-smartbond-bluetooth-low-energy-%E2%80%93-software/da14680-whitelist-ble, there is no whitelist for central device address in 14680? Is it still the same case for 14682?

If both of them are true, how can I achieve my goal easily?

Thanks!

Yingfen

Device:
PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi yingfen,

Hi yingfen,

Yes, both DA14680/1 and DA14682/3 use the same SDK and there isn’t any API for whitelisting functionality in our current SDK. However. I ‘ll ask internally if we include whitelisting API in our future SDK release.

Thanks, PM_Dialog

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

谢谢你的回复。所以除了白名单,曲线ntly there is no existing internal function we can use to filter the central device, but have to do it externally?

Thanks,

Yingfen

PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi yingfen,

Hi yingfen,

Can you please provide me more inputs regarding your requirement in order to understand what you are trying to accomplish? If I am not mistaken, the Peripheral is a DA14682 chip, but what about the Central device?

Regards, PM_Dialog

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

Both the peripheral and central devices are using the same da14682 chips. I wonder if there is a way that our peripheral can only connect to our central (by Mac address/device name or other methods are OK) devices, and reject other connection requests. We have mutiple centrals and multiple peripherals. One peripheral can connect to multiple centrals and vice versa.

If there are any existing demos, I can also read and follow them.

Thanks,

Yingfen

PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi yingfen,

Hi yingfen,

如果外围知道的BD地址分ral, and vice versa, directed advertising could be achieved.But not sure, if this is possible when peripheral should be connected with multiple Centrals. I have to ask it internally and I will let you know. There isn’t any available demo for that.

Thanks, PM_Dialog

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

Thanks. I will wait for it.

Yingfen

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

Any updates since last week? It will be great if we don't need to check the central device manually.

Thanks,

Yingfen

PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi yingfen,

Hi yingfen,

Apologies for the delay. White list is not supported in our SDK. Whitelist management API is not present in this release, so setting a filtering policy for advertising is not possible. I ‘m trying to figure out how you can do it…

Thanks, PM_Dialog

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

谢谢你的回复。We can wait for it as it's not an urgent task. But it will make our system more secure, so we also hope we can add the feature to it.

Thanks,

Yingfen

PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi yingfen,

Hiyingfen,

Apologies for the delay, hope I can help. Each peripheral can populate an unique ID (encrypted or decrypted). Each central will scan over the air, and if I get’s the proper ID from the peripheral, then the connection should be achieved. You can also add authentication in your design.

Thanks, PM_Dialog

yingfen
Offline
Last seen:1 year 6 months ago
Joined:2019-08-07 00:10
Hi PM_Dialog,

Hi PM_Dialog,

I think the solution is from the central side, not the peripheral side.

1. For the central side, we currently use the device name as a filter. But the solution you referred to seems to be better. Can you explain in detail about how to populate the unique ID for the peripheral? Or is there any demo?

2. But the question in this thread we want to ask is from the peripheral side: If an unknown central device wants to connect with our peripheral, how the peripheral knows it's unknown and rejects this connection request?

Thanks,

Yingfen

PM_Dialog
Offline
Last seen:37 min 39 sec ago
Staff
Joined:2018-02-08 11:03
Hi Yingfen,

Hi Yingfen,

White-list feature is not supported for DA1468x. To do so, if you would like to be connected with a specific Central, you should reject the connection inside your application. You can check the Central’s BD address, so the application will decide either to reject or keep the connection. Regarding the ID, it could be placed into the advertising data.

Thanks, PM_Dialog