Hello, can't find related forum section. We try to connect SC14CVMDECT to spectralink dect server + base station. And it connect successfully. SC14CVMDECT is registered on the server. I see that. Settings:
DectMode:EU_DECT
PI_PROD_TEST_REQ (ImageInfo)
ImageStatus: 0:FP_CVM = RSS_OFFLINE: Image Disabled.
1:PP_CVM = RSS_SUCCESS: Image is running.
2:COLA = RSS_OFFLINE: Image Disabled.
on the server, SC14CVMDECT IPEI is given a phone number.
I tried calling from a dect phone to SC14CVMDECT. And it doesn't work. SC14CVMDECT doesn't answer. Server logs says Timer expired. I have tried using sendmail to have the device respond, but to no avail (Sendmail.exe 3 1 4929)
Please help.
Device:
Hello Sergey,
Let me raise this internally.
Kind regards,
Elliott Dexter
你好,任何新s? or when to expect news?
Best regards,
sergey.kovalev
Hello Sergey,
I raised this with the internal applications team on wednesday, so I should expect a response soon.
Kind regards,
Elliott Dexter
thanks for the information, will it be this week?
Hello Sergey,
From the message displayed, the SC14CVMDECT module is configured as PP host command mode which required an external MCU running an application software to exchange command/status with the DECT stack module using the message sequence in API manual to complete your intended operation.
I would suggest you to follow the instruction in either "SC14CVMDECTDEVKT_Example Pendant_v3.1" or "SC14CVMDECTDEVKT_Example Conferencing_v3.17" document in our SDK to verify your setup in COLA mode using pair of SC14CVMDECT module. If successful, use the PP part and experiment again with Spectralink DECT server.
Please remember SC14CVMDECT module requiring an application software running on top to become a workable portable part.
Regards, WC Ip