Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
6 posts / 0 new
Last post
sergey.kovalev
Offline
Last seen:2 years 9 months ago
加入:2018-07-17 12:28
SC14CVMDECT and spectralink dect base station

Hello, can't find related forum section. We try to connect SC14CVMDECT to spectralink dect server + base station. And it connect successfully. SC14CVMDECT is registered on the server. I see that. Settings:
DectMode:EU_DECT
PI_PROD_TEST_REQ (ImageInfo)
ImageStatus: 0:FP_CVM = RSS_OFFLINE: Image Disabled.
1:PP_CVM = RSS_SUCCESS: Image is running.
2:COLA = RSS_OFFLINE: Image Disabled.

on the server, SC14CVMDECT IPEI is given a phone number.

I tried calling from a dect phone to SC14CVMDECT. And it doesn't work. SC14CVMDECT doesn't answer. Server logs says Timer expired. I have tried using sendmail to have the device respond, but to no avail (Sendmail.exe 3 1 4929)

Please help.

Device:
ED_Dialog
Offline
Last seen:1 month 4 weeks ago
工作人员
加入:2017-09-18 11:54
Hello Sergey,

Hello Sergey,

Let me raise this internally.

Kind regards,
Elliott Dexter

sergey.kovalev
Offline
Last seen:2 years 9 months ago
加入:2018-07-17 12:28
Hello, any news? or when to

Hello, any news? or when to expect news?

Best regards,
sergey.kovalev

ED_Dialog
Offline
Last seen:1 month 4 weeks ago
工作人员
加入:2017-09-18 11:54
Hello Sergey,

Hello Sergey,

I raised this with the internal applications team on wednesday, so I should expect a response soon.

Kind regards,
Elliott Dexter

sergey.kovalev
Offline
Last seen:2 years 9 months ago
加入:2018-07-17 12:28
thanks for the information,

thanks for the information, will it be this week?

WI_Dialog
Offline
Last seen:56分钟前6天
工作人员
加入:2014-01-03 16:21
Hello Sergey,

Hello Sergey,
From the message displayed, the SC14CVMDECT module is configured as PP host command mode which required an external MCU running an application software to exchange command/status with the DECT stack module using the message sequence in API manual to complete your intended operation.
I would suggest you to follow the instruction in either "SC14CVMDECTDEVKT_Example Pendant_v3.1" or "SC14CVMDECTDEVKT_Example Conferencing_v3.17" document in our SDK to verify your setup in COLA mode using pair of SC14CVMDECT module. If successful, use the PP part and experiment again with Spectralink DECT server.
Please remember SC14CVMDECT module requiring an application software running on top to become a workable portable part.
Regards, WC Ip