USER_ADVERTISE_DATA

⚠️
Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
12 posts / 0 new
Last post
鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
USER_ADVERTISE_DATA

Hello Dialog_Support,

1我们正在将DA14580 MCU配置为广播员模式。所以我们需要动态地改变USER_ADVERTISE_DATA字符串以发送动态更改的数据。但是这个用户数据是在USER\u config.h文件中定义的,所以我们不能修改它。是否有任何规定,以便我们可以修改用户定义函数中的用户数据?

2. Can we define more than one USER_ADVERTISE_DATA?
for example
#define USER_ADVERTISE_DATA ("\x03"\
ADV_TYPE_COMPLETE_LIST_16BIT_SERVICE_IDS\
ADV_UUID_DEVICE_INFORMATION_SERVICE\
“\x11”\
ADV_TYPE_COMPLETE_LIST_128BIT_SERVICE_IDS\
"\x2F\x2A\x93\xA6\xBD\xD8\x41\x52\xAC\x03\x00\x0F\xCA\xEA\x80\x7F")

#define USER_ADVERTISE_DATA1 ("\x03"\
ADV_TYPE_COMPLETE_LIST_16BIT_SERVICE_IDS\
ADV_UUID_DEVICE_INFORMATION_SERVICE\
“\x11”\
ADV_TYPE_COMPLETE_LIST_128BIT_SERVICE_IDS\
“\x2F\x2A\x93\xA6\xBD\xD8\x41\x52\xAC\x03\x00\x0F\xCA\xEA\x80\x00”)

The above mention code snippet is possible or not?

3.如果我们想发送超过广告ckets with different payloads then do you have any example code?

4. How to change advertisement packet transmission rate?

Device:
PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
Hi Ruchi Patel

Hi Ruchi Patel

请查看SDK的ble\u app\u barebone示例,它演示了用户广告数据的动态变化。是的,您可以用不同的有效负载发送1个以上的广告包。ble\u app\u barebone示例也演示了该功能。广告字符串应该有一个特定的格式,如。您发布的代码块具有这种格式,因此可以这样做。广告包传输速率可以在的用户无向广告配置结构中定制
用户配置.h文件。广告分组在特定的广告间隔中传输,该广告间隔可以在该结构中改变

Thanks PM_dialog

鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
Hello PM_Dialog,

Hello PM_Dialog,

Thank you for your prompt reply. It was helpful.
我还有几个问题。
1. I have checked ble_app_barebone example. In that, only manufacturing advertising data are changing. If we want to modify other bytes of advertising data in user files then how we can modify? Do you have any example program for this?
2. I have not found user_undirected_advertise_conf structure in ble_app_barebone example so can you tell me in which example this structure is defined?
3.I want to configure one broadcaster which transmits advertising packets. This advertising packet we can modify. We should able to modify more than 1 bytes of advertising data. So can you guide me how to start this?

Thanks and Regards,
鲁奇帕特尔

PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
你好,鲁奇·帕特尔,

你好,鲁奇·帕特尔,

您可以通过更改user\u adv\u conf结构(在user\u config.h中定义)的.intv\u min或.intv\u max菜单来配置播发数据包传输速率。这样,您就可以定义广告的最小和最大间隔。关于广告数据,您不仅可以修改生产广告数据。您还可以修改超过1字节的广告数据。SDK的ble\u app\u barebone示例动态更改广告字符串的适当性数据。在特定示例中,property数据的长度为2字节,但其长度可以更改。在广告字符串中,您可以附加特定的数据并从应用程序中更新它们。广告消息在app\u easy\u gap\u undirected\u advertise\u start\u create\u msg()函数中创建,然后在调用app\u easy\u gap\u undirected\u advertise\u get\u active()函数时保存在cmd结构中。cmd指针将有一个完整的消息,您可以将它发送到堆栈,其中包括一些默认的adv数据,这些数据来自用户advise数据,因此您可以在app easy\u gap\u undirected\u advised\u get\u active()返回后执行,将包含广告数据的cmd指针中的数组作为目标(cmd->info.host.adv_data)并根据您的喜好进行更改—您的数据必须符合BLE规范。

Thanks PM_dialog

鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
Hello PM_dialog,

Hello PM_dialog,

Thank you for the reply. Now I am able to send more than 1 bytes in USER_ADVERTISE_DATA. Next I want to do role switch between observer and broadcaster. I have two individual applications: one as a broadcaster and other as a observer. Previously i have done role switching between peripheral and central. So i have tried to configure this but my application goes into nmi_handler as i run the application. Can you suggest me that is there any extra changes required?

Thanks and Regards,
Ruchi

PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
你好,鲁奇·帕特尔,

你好,鲁奇·帕特尔,

关于NMI_handler是独立于你dual-role application. The NMI_handler will be issued due to the WatchDog timer. Please check where the Watchdog hits into your application. Regarding the switching between broadcasting and observer mode, you shouldn’t do any additional changes. In the case of the broadcasting are you advertising as a non-connectable device? If not, you can use the app_easy_gap_non_connectable_advertise_start API to create the advertising message for non-connectable advertising. Also, I suggest you to use the .app_on_adv_nonconn_complete callback function when the advertising is done since this callback is triggered when advertising as a non-connectable device.

Thanks PM_dialog

鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
Hello Dialog_Support,

Hello Dialog_Support,

Thank you for your reply. Now i am able to switch the role from observer to broadcaster and vice versa.

1我在我的第一篇文章中问过我们可以定义多个用户数据吗?. 我可以在user\u config.h文件中定义它。但是怎么称呼呢?我的意思是nvds.c文件具有nvds\u data\u struct结构,在该结构中调用了用户数据。但是如果我想调用USER\u adversed\u DATA和USER\u adversed\u DATA1,那么我可以在哪里调用用户空间呢?由于nvds.c文件是SDK的公共文件,所以我不能修改它。

2. I have one broadcasting device in which i am modifying manufacture data which is part of USER_ADVERTISE_DATA and start advertising. At the other end I have another device which is observer. At observer side I am getting USER_ADVERTISE_DATA packets but in that I am not getting manufacture data. I have checked using BLE Scanner App, In that i am getting manufacture data. How to receive this manufacture data at observer device side?

Thanks and Regards,
Ruchi

PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
嗨,鲁奇·帕特,

嗨,鲁奇·帕特,

The #define “USER_ADVERTISE_DATA” is appended into the .NVDS_TAG_APP_BLE_ADV_DATA item of nvds_data_storage structure as you said in your post. You can define more than one USER_ADVERTISE_DATA, but only one of that can be appended in that structure due to the unique .NVDS_TAG_APP_BLE_ADV_DATA item. If you want to have more than one advertising data, you are able to do it but with a different way. I suggest you to define the USER_ADVERTISE_DATA as empty, and then append your different advertising data dynamically. When the device starts advertising, the user_app_adv_start() is executed and then the cmd is created by app_easy_gap_undirected_advertise_get_active(). The app_easy_gap_undirected_advertise_get_active() function returns the app_easy_gap_undirected_advertise_start_create_msg() function which creates the advertising message for a connectable undirected event. The advertising message includes the user advertising configurations, the advertising data and other data. The app_easy_gap_adv_read_from_NVDS() function reads USER_ADVERTISE_DATA from the nvds_data_storage structure, so if you have empty the USER_ADVERTISE_DATA define, your advertising data will be empty. By this way, you are able to append your different advertising data depending on your application dynamically by using app_add_ad_struct() in the user_app_adv_start() function.

Regarding the manufacturer data, when the device is in observer mode, the .app_on_adv_report_ind ind callback function (in user_callback_config.h file) will executed, so it shouldn’t be NULL and you should define a function to be triggered. When a GAPM_ADV_REPORT_IND is received, the gapm_adv_report_ind_handler() will executed which is executes the .app_on_adv_report_ind ind callback. This handler has input parameter the gapm_adv_report_ind structure, which includes the adv_report structure. The manufacturer data should be at the data[ADV_DATA_LEN] item of the adv_report scucture. So how do you actually check that the manufacturer data are not being received and all the other data received properly?

Thanks PM_dialog

鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
Hello PM_Dialog,

Hello PM_Dialog,

1. In user_config.h file, I will keep USER_ADVERTISE_DATA as empty and later I will add advertising data dynamically. But is it possible to add large number of bytes(approximately 16-20 bytes) into single USER_ADVERTISE_DATA? Let's consider I am able to broadcast large number of bytes but at the observer side, can I receive more than 31 bytes data? Right now, if broadcaster has large number of bytes in USER_ADVERTISE_DATA then at observer side I am not able to receive advertising data bytes more than 31 bytes.

2. I am observing data in user_on_adv_report_ind function. Here i am attaching code snippet of that function.
void user_on_adv_report_ind (struct gapm_adv_report_ind const * param)
{
volatile static uint8_t param_data[ADV_data_LEN];

拱形\u printf(“%02x%02x%02x%02x%02x%02x%02x%02x%02x%02x%02x%02x%02x\n\r”,
param - > report.adv_addr.addr [5],
param - > report.adv_addr.addr [4],
param - > report.adv_addr.addr [3],
参数->report.adv_addr.addr[2],
参数->report.adv_addr.addr[1],
param - > report.adv_addr.addr [0],
param_data[0] = param->report.data[0],
param_data[1]=参数->report.data[1],
param_data[2]=参数->report.data[2],
param_data[3] = param->report.data[3],
param_data[4] = param->report.data[4],
param_data[5] = param->report.data[5],

像这样,我正在读取31字节的数据。我不知道其他读取数据的方法。在广播端,在26字节之后,附加制造数据。如果我在manufacture data string修改我的自定义数据,并且广告数据长度超过31字节,那么我在observer端得到00,但是如果我在Raw data部分的BLE Scanner应用程序中选中相同的,我得到的是我修改过的相同数据。你能解释一下为什么会这样吗?如果您有任何其他方法读取用户数据,请告诉我。

Thanks and Regards,
Ruchi

PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
你好,鲁奇·帕特尔,

你好,鲁奇·帕特尔,

Depending how you are using the SDK and which example you are using be aware that the SDK will append any extra data that don’t fit in the advertising string in the scan response data, so make sure that the data that you are interested in is in the advertising string and not the scan response data. In the first indication (advertising indication) the advertising data will populate the data member of the adv_report struct, and then in the second indication (scan response indication) the scan response data will populate the struct. In order to catch the scan response data, you should configure your device as GAPM_SCAN_ACTIVE to get a scan response. If you configure your device as GAPM_SCAN_PASSIVE, the observer only receives advertising data and doesn’t send a scan request to receive a scan response, so you will not able to read your scan response data. I’ve also tested this using an observer and the ble_app_barebone, I was able to get the increment in the advertising string or in the scan response data.

Thanks PM_dialog

鲁奇帕特尔
Offline
最后一次见到:2 years 6 months ago
Joined:2017-03-29 10:50
Hello PM_Dialog,

Hello PM_Dialog,

Thank you for the response. I am developing my application by taking reference of ble_app_peripheral and ble_app_barebone example. Now i want to send my custom data into USER_ADVERTISE_DATA but that data don't fit into USER_ADVERTISE_DATA so as i asked in my previous post that can we define multiple USER_ADVERTISE_DATA and broadcast it? But as USER_ADVERTISE_DATA is invoked in nvds.c file which is DSK's common file so I can't modify it. As you have suggested that update USER_ADVERTISE_DATA but i am not able to implement that so can you provide me any code snippet or example code which is doing exactly same.

简而言之,我想一次向4个不同的观察者广播28个字节。所以,如果我可以发送7字节每个广告包和4个广告包,我想广播的时间,然后什么配置我需要遵循?请帮帮我。

Thanks and Regards,
鲁奇帕特尔

PM\U对话框
Offline
最后一次见到:9 hours 47 min ago
Staff
Joined:2018-02-08 11:03
你好,鲁奇·帕特尔,

你好,鲁奇·帕特尔,

As I have pointed out in a previous post, you are not able to define more than one USER_ADVERTISE_DATA, because the #define “USER_ADVERTISE_DATA” is appended into the .NVDS_TAG_APP_BLE_ADV_DATA item of nvds_data_storage structure. The advertising string has 31 byte length, but 3 bytes of them are reserved from the stack, the advertising filter policy and the advertising data length, so you are able to use up to 28bytes. The data that are appended into the advertising string will be populated by user_app_adv_start with the procedure I have already mentioned in a previous post. In case you want to add your custom data into the advertising string you should copy them into the correct array of the cmd which is into user_app_adv_start() function. The cmd is created by app_easy_gap_undirected_advertise_get_active(). In your application you can have the USER_ADVERTISE_DATA empty and copy your data into the advertising string. The custom data should be valid and should follow the structure of USER_ADVERTISE_DATA, as in order to start advertising correctly. You should have 2bytes as length and flag into your data, so finally you are able to append up to 26bytes into the advertising string. In the following code, I will present you how you can do that.

void user_app_adv_start(void)
{

uint8\u t advdata[28]={0x1B,0xFF,0x31,0x32,0x33,0x34,0x35,0x36,0x37,0x38,0x39,0x31,0x32,0x33,0x34,0x35,0x36,0x37,0x38,0x39,0x31,0x32,0x33,0x34,0x35,0x36,0x37,0x38};

//安排下一次广告数据更新
app_adv_data_update_timer_used = app_easy_timer(APP_ADV_DATA_UPDATE_TO, adv_data_update_timer_cb);

struct gapm_start_advertise_cmd* cmd;
cmd = app_easy_gap_undirected_advertise_get_active();

memcpy(cmd->info.host.adv_data, advdata , 28);

//动态添加特定于制造商的数据
//mnf_data_update();
app_add_ad_struct(cmd,&mnf_data,sizeof(struct mnf_specific_data_ad_structure));

app_easy_gap_undirected_advertise_start();
}

如果将26字节的数据添加到播发字符串中,并希望填充其他数据,则可以将它们附加到扫描响应数据中,但在另一侧,观察者应配置为GAPM\u scan\u ACTIVE,以便发送扫描请求。

Thanks PM_dialog