Interfacing sensor interrupts to P1_2 & P1_3 pins

⚠️
Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
2 posts / 0 new
Last post
sr9213
Offline
Last seen:2 weeks 4 days ago
Joined:2017-09-26 11:30
Interfacing sensor interrupts to P1_2 & P1_3 pins

Hi,
In the datasheet, it was mentioned that due to the crosstalk between XTAL16Mp and P1_2 and P1_3 pins of DA14585, an error may occur during transmission. Is it safe to connect sensor interrupts lines to these pins.

Thanks and Regards,
Sai Ram

Device:
MT_dialog
Offline
Last seen:1 month 3 weeks ago
Staff
Joined:2015-06-08 11:34
Hi sr9213,

Hi sr9213,

There is an issue if those specific GPIOs toggle, if that occurs, then you wont be able to transmit or receive, so if you are going to place sensors on those lines the problem depends on how often those lines will toggle.

Thanks MT_dialog