Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.xmece.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
2 posts / 0 new
Last post
tektronic
Offline
Last seen:3年2蒙特hs ago
加入:2017-05-06 15:06
DA14680

Hello,

I try to understand the Keyboard scanner of DA14680. DS pg. 125, 28.2 Programming - states:

"Following that, the columns have to be programmed in output mode ....
The columns have to be explicitly defined as pulled-up inputs ....."

From above it looks like "the columns" should be outputs and inputs ?
Can you clarify ?

Thank you.

Device:
MT_dialog
Offline
Last seen:2 months 1 week ago
工作人员
加入:2015-06-08 11:34
Hi tekronic,

Hi tekronic,

The rows have to be programmed in OUTPUT mode with a dedicated functionallity KB_ROW and the columns have to be set as input pull-up with functionallity as a plain GPIO, seems that there is an error in the datasheet.