Hello,
I try to understand the Keyboard scanner of DA14680. DS pg. 125, 28.2 Programming - states:
"Following that, the columns have to be programmed in output mode ....
The columns have to be explicitly defined as pulled-up inputs ....."
From above it looks like "the columns" should be outputs and inputs ?
Can you clarify ?
Thank you.
Device:
Hi tekronic,
The rows have to be programmed in OUTPUT mode with a dedicated functionallity KB_ROW and the columns have to be set as input pull-up with functionallity as a plain GPIO, seems that there is an error in the datasheet.