嗨对话框,
我有以下设置为生产线工具将第二个引导加载程序编程到OTP中,以及我的ETA中的组合图像进入闪存。
但是我收到了如下所示的错误日志,您有建议和解决方案吗?我还附上了图片的图片
11:48:45:409 [debug] [u_dll] [udll_dbg_init |296] >>> dbg_enable = [1],dbg_level = [0x5],dbg_out = [0x4],dbg_clbk = [0xd80a7e],dbg_file_path = [udll_debug.txt]
11:53:01:569 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [9]上不匹配
11:53:01:599 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [8]上不匹配
11:53:01:599 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [16]上不匹配
11:53:01:649 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [7]上不匹配
11:53:01:649 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [11]上不匹配
11:53:01:649 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [6]上不匹配
11:53:01:649 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [14]上不匹配
11:53:01:709 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [4]上不匹配
11:53:01:709 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [18]上不匹配
11:53:01:709 [错误] [u_dll] [udll_main_thread |1272] >>>错误:OTP图像文件在COM端口= [12]上不匹配
11:53:29:439 [错误] [u_dll] [close_device |2652] >>>错误:wainforsingleObject在device_opts_t-> ovlrd.hevent wait_timeout com_port = [8]
11:53:30:439 [错误] [u_dll] [close_device |2687] >>>错误:wainforsingleObject在device_opts_t-> hthread wait_timeout com_port = [8]
11:53:30:469 [错误] [u_dll] [print_sys_error |4544] >>>错误:6:句柄无效。
11:53:30:469 [错误] [u_dll] [reset_buffer |2424] >>>错误:用柄= [CB8] com_port = [8]
11:53:30:469 [错误] [u_dll] [udll_main_thread |976] >>>错误:COM端口上的缓冲区重置= [8]
11:53:31:549 [错误] [u_dll] [close_device |2652] >>>错误:wainforsingleObject在device_opts_t-> ovlrd.hevent wait_timeout com_port = [7]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [16]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [16]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [12]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [9]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [18]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [11]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [14]
11:53:31:679 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [14]
11:53:32:549 [错误] [u_dll] [close_device |2687] >>>错误:wainforsingleObject在device_opts_t-> hthread wait_timeout com_port = [7]
11:53:32:549 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [0]
11:55:33:509 [错误] [u_dll] [close_device |2652] >>>错误:wainforsingleObject在device_opts_t-> ovlrd.hevent wait_timeout com_port = [8]
11:55:34:509 [错误] [u_dll] [close_device |2687] >>>错误:wainforsingleObject在device_opts_t-> hthread wait_timeout com_port = [8]
11:55:34:509 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [0]
11:55:35:509 [错误] [u_dll] [close_device |2652] >>>错误:wainforsingleObject在device_opts_t-> ovlrd.hevent wait_timeout com_port = [7]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [12]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [12]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [16]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [9]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [4]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:COM端口上的FW下载= [14]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [18]
11:55:35:759 [错误] [u_dll] [udll_main_thread |966] >>>错误:FW下载COM端口= [18]
嗨Liuluan002,
请您报告您正在使用的PLT SW的版本,也可以上传PARAMS.INI和PARAMS.xml文件以查看?
谢谢mt_dialog.
嗨对话框,
我正在使用PLT SW:“DA14580 / 581生产线工具v_3.170.2.36”
我只找到了“params.ini”并附上了文件,我尚未找到“params.xml”,可以帮忙吗?
嗨对话框,
我在previoully评论中有updaload的params.ini,你可能需要看看。
布罗尔,
Liuluan002.
嗨对话框,
The chipset I am trying to program is DA14583, Since I I read the UM-B-012, seems it already comes out the second bootloader in the OTP, right now I want to update my second bootloader, is any special setting I needs to make to make the PLT works for our production?
嗨Liuluan002,
params.ini是PLT版本的正确配置文件Params.xml文件是用于最新版本的PLT。还有一个额外的问题,直到团队检查配置文件,我想你已经应用了VPP才能刻录你的OTP?还可以检查PC是否识别PC的COM端口?
关于引导加载程序和583,您可以将额外的引导加载程序刻录到称为高级引导加载程序的583(是辅助引导加载程序以实现双重图像),583将如何了解高级引导程序取决于0x7F10OTP标题上的地址,它决定了高级引导加载程序的偏移量和长度。关于我是否有一个特殊的设置我正在与我们的PLT专家一起检查,我会尽快通知您,我会有一些反馈您获得的错误。
谢谢mt_dialog.
当我编写OTP时,我已经测量了VPP的电路板,它将它进入6.8V。此外,我也用具有相同PLT的OTP标题成功编程了一个新的DA14583板(应用标志1和荣笛2是否,DMA长度我使用03 BD而不是1F C0。),但我没有用第二个编程OTP图像。引导加载程序。
我今天也只制作闪光部分,一次为64个单位编程为16个单位,OTP图像和OTP标题未编程。它显示PC识别PLT工具的所有17个COM端口。17 COM港口令人犯了16 DUT和1金单位。
嗨Liuluan002,
就我可以通过PLT工具告诉OTP没有提供额外的图像,因此PLT在特定的偏移(从OTP图像开始时开始写入OTP),没有选项燃烧OTP在特定的偏移量上,我仍在检查PLT专家来获得一些反馈。我假设你得到的错误是因为你用高级引导加载程序覆盖了工厂583引导加载程序,当工具读回验证时,它会获得两个引导加载程序的ORED值。检查是否可以检查是否可以进行工作,也许通过添加到高级引导程序映像将0x00填充到应位于高级引导加载程序所在的地址。
谢谢mt_dialog.
是因为它是由于从工厂预先制作的第二引导加载程序和OTP中的高级引导加载程序的重叠使系统无法启动,是此问题的任何解决方案吗?
嗨Liuluan002,
如上所述,仍在等待答复,我会尽快通知您,只要我得到了PLT专家的回复。
谢谢mt_dialog.
你好,
我有一个来自客户获取的PLT硬件,以开发其产品的测试/编程。我的软件是CSharp。我想支持如何在CSharp中使用PLT DLL库。请提供联系方式。
嗨anunez,
我们将通过邮件与您联系。
谢谢mt_dialog.
嗨对话框,
这个问题有什么更新吗?
嗨Liuluan002,
对不起,迟到的回复,但PLT专家很忙,所以,随着我的知情,PLT没有规定在583中刻录高级引导加载程序,PLT假设应该始终写入OTP地址0以便从那里引导。因此,您可以遵循以下准则,以便通过PLT工具测试在OTP中刻录高级引导加载程序:
谢谢mt_dialog.
你好,
您可以提出建议如何激活循环并重置DA14581芯片。是否有生产线工具命令行或使用DLL?