The question of PLT

Because here can not use pictures, so I write the question in the attachment "the issue of PLT 20161122," please refer to.

Thank you very much!

Keywords:
Device:
Qinjiny_Dialog
Offline
Last seen:The two have three weekes line
The Staff
Joined:The 2016-11-01 05:47
hello

hello

Can you try to please the application in the attribute is set to Windows 7 (or other than win10 older version) compatible mode, see if I can repair your UI dislocation

We will see your reflection in win10 environment test software problem is widespread, if it is we will check in the updated version to repair as soon as possible

In addition to the UI program and other practical use on the problem?

Regards,

z0806020433
Offline
Last seen:1 year 2 have a line
Joined:The 2016-05-05"
Hello!

Hello!
As you suggest, in the attribute set after the compatibility mode (doing Windows 7 Windows xp), UI display or before as the attached picture.

Using this software the function is normal, if I want to use this software in the OTP HEADER address 0 x47fdc into 4 bytes, four bytes that represents an integer, identified as ID number of the equipment.
Such as writing hex 0 x0000010a represent decimal 266.And the ID and MAC address binding, the MAC address automatically add 1, this ID also can automatically add 1, so that I can use this software at the same time burning more
Equipment, so that each device have an own ID and MAC.

Can you help to modify the custom?

Qinjiny_Dialog
Offline
Last seen:The two have three weekes line
The Staff
Joined:The 2016-11-01 05:47
hello

hello

Have been run on win10 PC V3.1 (support site to download version), and no you describe UI dislocation phenomenon.Please make your own to find if there are other causes of the problem.

About you mentioned the function, can try to modify the software included with the source code and recompile implementation, this does not have the function that extensive demand we can't contact PLT customized software developers

Here some information about source code, hope to help you:

About custom OTP burning function in the source \ production_line_tool \ u_dll \ U_dll_580 c file:

# define OTP_580_CUSTOMER_FIELD_ADDR 0 XXXXXX on behalf of the user custom content burn address, 0 x47fdc can be modified as you need

Otp_set_custom_field function is used to read the user input in GUI 16 bytes of custom content and written to the above address

Otp_set_bd_addr function for reading device bluetooth address and written into a specific address, device_opts_t - > udll_device_params. Bd_addr for current is used to write OTP bluetooth address, length is 6 bytes

Can by simply replaced or build new variables to the address you need write bluetooth address after four bytes, need to customize the data need more modification

z0806020433
Offline
Last seen:1 year 2 have a line
Joined:The 2016-05-05"
Hello!

Hello!
On GUI dislocation phenomenon, I run on Windows 7 V3.1 also is to have the same problem.You let myself to find the reason, I do not know how to start, if I need to install other software resources in order to support the running of PLT software?Can you provide some information to find the reason to me?

Qinjiny_Dialog
Offline
Last seen:The two have three weekes line
The Staff
Joined:The 2016-11-01 05:47
In addition, please your ref from the support website

Another ref please from the support website design plate download discharges the PLT_v3. 1 version to try to see if there is the same problem

thank you

z0806020433
Offline
Last seen:1 year 2 have a line
Joined:The 2016-05-05"
Hello!

Hello!
Download PLT_v3. 1, run version of v_3 170.6.90, the same problems.Are win10 systems we use now, so trouble on win10 confirm this problem, and help me fit.
Thank you very much!