Skip to main content

DA14580 Development Kit - Basic

停止

TheDA14585 and DA14586are available for new designs.

DA14580 Board – Basic

Get ahead of the competition

This DA14580 basic development kit gives you all flexibility to develop with confidence. All of the DA14580’s I/Os are available and mapped on to expansion connectors. A debugger is provided on the PCB which in combination with SmartSnippets™, Dialog’s complete software environment, enables you to program and test your applicatiions.

SmartBond™:power, size and system cost without compromise

Features

All flexibility

All I/O’s available and mapped on to expansion connectors

Onboard debugger

Complete software environment available

Starter kit

Board

Battery

USB cable

Quick starting guide

产品Briefs and Summaries
Name Date Version
SmartBond™ DA1458x Family Product Brief(2.82 MB) 22/06/2017 1.0
Datasheets
Name Date Version
DA14580 Datasheet(2.64 MB) 09/11/2016 3.4
Application notes
Name Date Version
AN-B-052 DA145Xx/68x Development Kit J-Link Interface(492.82 KB) 14/02/2017 1.0
Design tools
Name Date Version
DA14580 DEVKT -Basic: Electrical Schematic, BOM-, Layout-, Design- and Gerber-files(1.64 MB) 08/10/2018 2.3
Video thumbnail, click to open and play

SmartBond™ DA14580 - Development Kit - Basic

Buy now

产品 Shop
DA14580 Development Kit - Basic DA14580DEVKT-B Digikey Mouser Avnet Silica Avnet US Farnell
Back to results

2 weeks ago

DUT_PDLL_RX_TIMEOUT

Posted byandreswong75 points 13 replies
0 upvotes

hi, i am trying to run the program but it gave me this xtal error. not sure where went wrong as i cant get the program to work as shown in the user manual.

thank you.

Attachment 大小
xtal error_0.txt 14.83 KB

2 weeks ago

andreswong 75 points
Attachment 大小
xtal error.txt 14.83 KB

2 weeks ago

PM_Dialog

Hi andreswong,

Thanks for your question online. Unfortunately, I am not able to open the attached .txt files. Can you please zip and attach them again?

Thanks, PM_Dialog

2 weeks ago

andreswong 75 points

done, thank you for the quick response

Attachment 大小
xtal error.zip 1.75 KB

2 weeks ago

andreswong 75 points

I tired to follow the usual manual from page 157 onwards, but could not get the green pass when operating the GUI part with the error of xtal trim not working.

2 weeks ago

PM_Dialog

Hi andreswong,

Thanks for attaching the log file.

1. According to the log file :DUT IC: DA1469x. But the DA14580 is selected on the forum post. So, could you clarify which BLE device you are using?

2. What are the connections between the DUT (DA14580 or DA1469x) and PLT?

3. What is the SW version that the Golden Unit is running? It is explained in section 7.5 GU Upgrade Application.

4.请做一个晶体修剪测试中描述交会tion 7.2.6.5 XTAL Trim (DA14580) or in 7.2.10.3 XTAL Trim (DA1469x). Make sure that “Burn to OTP” check-box in NOT selected.

Thanks, PM_Dialog

2 weeks ago

andreswong 75 points

Hi PM_Dialog,

1. I am currently using DA14580_RD_tester 078-55-D. However there is no option to click on the IC device and i check DA1469x instead. *the ble is DA14697, just checked it, the plt is DA14580*

2. I have connect 4 wires, to the PLT and DUT base on the user manual page 20. VBAT,DUT TX,DUT RX and GND.

3. Yes i have upgrade the GU to the latest version, app: v_5.0.4_PLT_v4.4 , ble: v_5.0.4.

4.i have done both xtal trim test as described. yet the error still appear. please advice thank you.

Thanks,

Andres

2 weeks ago

andreswong 75 points

2 weeks ago

andreswong 75 points

Hi PM_Dialog,

The screenshot is the file I used to upload for the image path. It that correct? I had tried different files, such as the one mention in the user manual "prox_reporter_580.bin" and it does not work still.

Thanks,

Andres

Attachment 大小
image path file 2.png 225.48 KB

2 weeks ago

PM_Dialog

Hi andreswong,

I assume that you have a custom design, so could you please clarify which BLE device you are using?

DA14580, DA14531, or DA1469x?

Thanks, PM_Dialog

2 weeks ago

andreswong 75 points

yes, I am using DA1469x

2 weeks ago

PM_Dialog

Hi andreswong,

According to the previously attached screenshot (image path file 2.png), you are using the prod_test_531.bin which is for DA14531 product family.

In case of DA1469x, please check sections 7.2.9, 7.2.10 , 7.2.11, 7.2.11 from the user guide :

//www.xmece.com/sites/default/files/2020-12/um-b-041_smartbond_production_line_tool_4v5.pdf

The prod_test_69x.bin should be used- see section 6.8.2 DA1469x Test Sequence

Thanks, PM_Dialog

2 weeks ago

andreswong 75 points

Hi,

I have change according to the user manual and it gives me another error now. Please advice as I am stuck with this for quite a long time already. The attached are setting/error image that I am currently facing, QSPI error

Thanks,

Andres

Attachment 大小
Test_station_1_20210430_DUT_000000000041_FAILED.zip 1.81 KB
bin file setting.png 237.87 KB
qspi error.png 263.2 KB

3 days ago

PM_Dialog

Hi andreswong,

Sorry for my late response. Let me check your attachments and I’ll get back to you ASAP. Profitably I’ll need to escalate it internally to check it out.

Thanks, PM_Dialog